From the top: AO, AC, MACD
On the vertical axis, 3 is AO, 2 is AC and 1 is MACD. The height is the row position, not the strength of the indicator.
Shows in 3 rows whether AO, AC and MACD rose or fell from the previous bar, and marks the bars where all 3 directions agree in the bottom row.
From the top: AO, AC, MACDOn the vertical axis, 3 is AO, 2 is AC and 1 is MACD. The height is the row position, not the strength of the indicator.
Green is an increase, red is a decreaseEach indicator is compared with its previous bar. If the value is the same, no mark is shown.
The bottom row is agreement of all 3At 0 on the vertical axis, blue is shown if all increase and magenta if all decrease. Bars without agreement are blank.
Compares the default settings and a settings change example on a screen with only this product applied.
Published example: M1. This is an example to explain the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the included version has display settings for the brand text and QR code. The example with changed settings is not a set of recommended values. Details can be checked in the full-size view. Also check the vertical axis and units of the separate window. Except for products with a fixed scale, the scale changes with the settings and the displayed range.
On the vertical axis, 3 is AO, 2 is AC and 1 is MACD. The height is the row position, not the strength of the indicator.
Each indicator is compared with its previous bar. If the value is the same, no mark is shown.
At 0 on the vertical axis, blue is shown if all increase and magenta if all decrease. Bars without agreement are blank.
Shows in 3 rows whether AO, AC and MACD rose or fell from the previous bar, and marks the bars where all 3 directions agree in the bottom row.
AO = SMA5(median of high and low) − SMA34(median of high and low), AC = AO − SMA5(AO), MACD = Fast EMA(close) − Slow EMA(close). For each, the values of the current bar and the previous bar are compared, and the increase or decrease is shown with a mark. The MACD signal line is not used. With Show the All-Same-Way Row=false the bottom row is not displayed.
Direction is displayed from bar 35 for AO, bar 39 for AC and bar 2 for MACD. Bars without the required comparison value and flat bars are blank. If Fast and Slow have the same period, MACD is always 0, and no marks appear for MACD or the agreement row. This is not Williams %R. There is no movable panel and no notification function.
Load the history in MT5, and first apply only this product to the chart.
On the vertical axis, 3 is AO, 2 is AC and 1 is MACD. The height is the row position, not the strength of the indicator.
Put the default and the change example on separate charts, and compare them with the same symbol, timeframe and history.
The value of the forming bar changes with price updates. Read it separately from closed bars.
| Included file | Purpose / location |
|---|---|
| TRI_Williams_Direction_Panel.ex5 | The MT5 main file. Place it in MQL5/Indicators. |
The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.
Extract the ex5 main file rather than leaving it in the compressed file.
In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.
Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.
First check with the default values. Changes and removal are done from the chart's 'Indicators List'.
Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.
There are 7 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.
InpFastEMAInpSlowEMAInpShowAllInpTriBrandShowInpTriBrandCornerInpTriBrandXInpTriBrandYIt does not place, modify or close orders. There are no notifications or emails either.
Values on the forming bar are updated. Differences in data provider, symbol, timeframe and history start position affect the values and initial values.
Check the scale of the separate window. Do not treat the state bar heights, price differences and ratio displays as the same scale.
Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.
The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.
Direction is displayed from bar 35 for AO, bar 39 for AC and bar 2 for MACD. Bars without the required comparison value and flat bars are blank. If Fast and Slow have the same period, MACD is always 0, and no marks appear for MACD or the agreement row. This is not Williams %R. There is no movable panel and no notification function.
Check the ranges and combinations in the settings. Inputs for methods not in use must also be within the allowed range.
AO = SMA5(median of high and low) − SMA34(median of high and low), AC = AO − SMA5(AO), MACD = Fast EMA(close) − Slow EMA(close). For each, the values of the current bar and the previous bar are compared, and the increase or decrease is shown with a mark. The MACD signal line is not used. With Show the All-Same-Way Row=false the bottom row is not displayed.
Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.
If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.
AO = SMA5(median of high and low) − SMA34(median of high and low), AC = AO − SMA5(AO), MACD = Fast EMA(close) − Slow EMA(close). For each, the values of the current bar and the previous bar are compared, and the increase or decrease is shown with a mark. The MACD signal line is not used. With Show the All-Same-Way Row=false the bottom row is not displayed.
Direction is displayed from bar 35 for AO, bar 39 for AC and bar 2 for MACD. Bars without the required comparison value and flat bars are blank. If Fast and Slow have the same period, MACD is always 0, and no marks appear for MACD or the agreement row. This is not Williams %R. There is no movable panel and no notification function.
Only MT5 itself and this manual. Account authentication, external indicators and DLLs are not required.