MT5 indicators← Williams AC Pattern Dots product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

Williams AC Pattern Dots

Places green or red diamond dots on bars where the AC values form one of 3 types of shape. You can select only the types you want to check.

Indicator name: Williams AC Pattern DotsMetaTrader 5Main chart

How to read the display

1Green: completion of a rising type2Red: completion of a falling type3The 3 types can be selected individually
Schematic diagram of how to read it. This is not an actual terminal screen.
1

Green: completion of a rising typeA green diamond on the low side of a bar where an upward AC type has formed.

2

Red: completion of a falling typeA red diamond on the high side of a bar where the opposite type has formed.

3

The 3 types can be selected individuallyAll are shown with the same dot shape. To examine which type it is, enable only 1 type.

Record of conditions metMT5 onlyNot a trading instruction
1

MT5 display and examples of changed settings

Compares the default settings and a settings change example on a screen with only this product applied.

Settings change example: these items are changed
Type that turns and passes through 0 / Cross Through 0
InpZeroCrossPattern
true → false
Type that returns 3 times on the opposite side of 0 / Three Bars Beyond 0
InpThreeBarPattern
true → false

All other inputs remain at their defaults. On a PC, the default is on the left and the change example on the right; at smartphone width they appear in the same order from top to bottom.

Default settingsInpZeroCrossPattern = true / InpThreeBarPattern = true
Williams AC Pattern Dots default settings
Default settings. A green diamond on the low side of bars where the upward AC pattern occurred.
View the screen in detail at full size
Williams AC Pattern Dots default settings (full size)
Example of changed settingsInpZeroCrossPattern = false / InpThreeBarPattern = false
Williams AC Pattern Dots example of changed settings
Example change: Cross Through 0 = false, Three Bars Beyond 0 = false. Only the turns on the same side of 0 are shown, and there are fewer diamonds than with the defaults.
View the screen in detail at full size
Williams AC Pattern Dots example of changed settings (full size)

Example shown: M1. This is an example for explaining the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the packaged version has display settings for the brand text and the QR code. The settings change example is not a recommended value. Details can be checked in the full-size view. Please also check the price scale of the main chart and the positions of the candlesticks.

2

How to read it in 30 seconds

Green: completion of a rising type

A green diamond on the low side of a bar where an upward AC type has formed.

Red: completion of a falling type

A red diamond on the high side of a bar where the opposite type has formed.

The 3 types can be selected individually

All are shown with the same dot shape. To examine which type it is, enable only 1 type.

3

What it measures

Places green or red diamond dots on bars where the AC values form one of 3 types of shape. You can select only the types you want to check.

How the calculation works

AC=AO−SMA5 of AO, and AO=SMA5−SMA34 of the median. Name the AC values A, B, C, D from oldest (A–E for the 5-bar type). Green type 1: all 4 values positive and A>B<C<D. Type 2: A, B and C negative, D positive, and A>B<C<D. Type 3: all 5 values negative and A>B<C<D<E. Red reverses all signs and comparisons. In every type, equal values do not pass. A dot is placed when any enabled type is completed.

Conditions and exceptions

Cross Through 0 requires not only a simple 0 cross but also the turn shape before it. Green in Three Bars Beyond 0 is a type formed while AC is below 0, and it does not need to cross 0. Setting all 3 types to false is a valid setting, but no dots appear. Detection starts at the 42nd bar of history at the earliest. The AC line itself and the type numbers are not drawn.

4

Situations for reading the display

Reading the line and mark conditions

Indicator
A green diamond on the low side of a bar where an upward AC type has formed.
Cross-check
Cross-check the prices and settings at the same time.
Check
Check which line is larger, how equal values are handled, and the relationship with the previous bar.
Caution
Arrows and dots are not recommendations to place or close orders.

Compare setting differences

Indicator
Example change: Cross Through 0 = false, Three Bars Beyond 0 = false.
Cross-check
Use the same symbol, timeframe and history.
Check
Look at how the changed setting relates to the increase or decrease and the position of the marks.
Caution
The published settings are not recommended values.

Reading intervals without marks

Indicator
Cross Through 0 requires not only a simple 0 cross but also the turn shape before it. Green in Three Bars Beyond 0 is a type formed while AC is below 0, and it does not need to cross 0. Setting all 3 types to false is a valid setting, but no dots appear. Detection starts at the 42nd bar of history at the earliest. The AC line itself and the type numbers are not drawn.
Cross-check
Check the required history and whether the conditions are met.
Check
Do not treat the absence of marks as the calculation having stopped.
Caution
Nothing may be displayed during periods when the conditions are not met.
5

Steps for checking the display

1

Apply with the defaults

Load the history in MT5, and first apply only this product to the chart.

2

Check the role of the display

A green diamond on the low side of a bar where an upward AC type has formed.

3

Comparing settings

Put the default and the change example on separate charts, with the same symbol, timeframe and history.

4

Distinguish the forming bar

Closed Bars Only defaults to true. With false, marks on the forming bar can change, so distinguish them from the record on closed bars.

6

Installation and checking the package contents

Included filePurpose / location
TRI_Williams_AC_Pattern_Dots.ex5The MT5 main file. Place it in MQL5/Indicators.

The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.

1

Extract the ZIP

Extract the ex5 main file rather than leaving it in the compressed file.

2

Open the data folder

In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.

3

Apply this product

Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.

4

Check the settings and display

First check with the default values. Changes and removal are done from the chart's 'Indicators List'.

Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.

7

Settings

There are 8 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.

Turn on the same side of 0

English item name
Turn on One Side of 0
Input name
InpTurnPattern
Default
true
Allowed range
true / false
Description
Whether to show type 1. Green is a shape that fell 1 time and rose 2 times on the positive side; red is the opposite.

Type that turns and passes through 0

English item name
Cross Through 0
Input name
InpZeroCrossPattern
Default
true
Allowed range
true / false
Description
Whether to show type 2. Green turns on the negative side, and only the last value becomes positive.

Type that returns 3 times on the opposite side of 0

English item name
Three Bars Beyond 0
Input name
InpThreeBarPattern
Default
true
Allowed range
true / false
Description
Whether to show type 3. Green has all 5 values negative, in a shape that falls 1 time and rises 3 times.

Show marks on closed bars only

English item name
Closed Bars Only
Input name
InpClosedBarsOnly
Default
true
Allowed range
true / false
Description
Default true. No mark is placed on the latest, forming bar. With false, the mark on the current bar may change or disappear. Internal calculation is also done for the current bar.

Brand and QR

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Allowed range
true / false
Description
Displayed with true. Calculated values do not change.

Brand position

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Allowed range
Top left / Bottom left / Bottom right / Top right
Description
The default is bottom left.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.
8

Usage specifications

Display only

It does not place, modify or close orders. There are no notifications or emails either.

Closed bars and history

Closed Bars Only=true is a setting that hides marks on the latest forming bar. Past results are not guaranteed to stay unchanged through corrections or additions to the history or changes of the start position. The internal series is calculated on the current bar as well.

Mark positions

For the upward pattern, a green diamond 10 pixels below the low; for the downward pattern, a red diamond 10 pixels above the high. The dot colors are not a trading recommendation.

Brand display

Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.

For on-screen display only

The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.

9

Troubleshooting and usage notes

No marks, or blanks in the middle

Cross Through 0 requires not only a simple 0 cross but also the turn shape before it. Green in Three Bars Beyond 0 is a type formed while AC is below 0, and it does not need to cross 0. Setting all 3 types to false is a valid setting, but no dots appear. Detection starts at the 42nd bar of history at the earliest. The AC line itself and the type numbers are not drawn.

All 3 types set to false

This is not a rejected setting but a valid setting that hides all dots. Setting at least 1 type back to true makes that type be detected.

The display differs from similar indicators

AC=AO−SMA5 of AO, and AO=SMA5−SMA34 of the median. Name the AC values A, B, C, D from oldest (A–E for the 5-bar type). Green type 1: all 4 values positive and A>B<C<D. Type 2: A, B and C negative, D positive, and A>B<C<D. Type 3: all 5 values negative and A>B<C<D<E. Red reverses all signs and comparisons. In every type, equal values do not pass. A dot is placed when any enabled type is completed.

Displays overlap

Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.

Marks are cut off at the edge of the screen

Some marks near the edge of the published image are partly cut off. On a real chart, adjust the display range of the vertical axis and the horizontal position. The full-size view is for checking details and does not restore information outside the image.

If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.

10

Technical information and specification details

Calculation and reference range

AC=AO−SMA5 of AO, and AO=SMA5−SMA34 of the median. Name the AC values A, B, C, D from oldest (A–E for the 5-bar type). Green type 1: all 4 values positive and A>B<C<D. Type 2: A, B and C negative, D positive, and A>B<C<D. Type 3: all 5 values negative and A>B<C<D<E. Red reverses all signs and comparisons. In every type, equal values do not pass. A dot is placed when any enabled type is completed.

Initial values and exceptions

Cross Through 0 requires not only a simple 0 cross but also the turn shape before it. Green in Three Bars Beyond 0 is a type formed while AC is below 0, and it does not need to cross 0. Setting all 3 types to false is a valid setting, but no dots appear. Detection starts at the 42nd bar of history at the earliest. The AC line itself and the type numbers are not drawn.

Package contents and dependencies

Only MT5 itself and this manual. Account authentication, external indicators and DLLs are not required.

Reservation on data display

The subwindow name and the Data Window items have not been verified. To see the values, check the items on an actual terminal.