MT5 indicators← Volume Quadrants product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

Volume Quadrants

Combines the increases and decreases of volume and true range and shows them as bars in 4 colors.

Indicator name: Volume QuadrantsMetaTrader 5Separate window

3 points of the display

1Bar size2Color classification3Bars with no histogram bar
Schematic diagram of how to read it. This is not an actual terminal screen.
1

Bar sizeThe absolute value is the current bar's tick volume.

2

Color classificationDivided into 4 groups by the changes of volume and True Range from the previous bar.

3

Bars with no histogram barIf either is equal to the previous bar, the bar is not classified and no value is output.

Tick volumeMT5 onlyColors and levels are not trading instructions
1

MT5 display and examples of changed settings

Compares the default settings and a settings change example on a screen with only this product applied.

Settings change example: these items are changed
Bar sign / Sign
InpSign
Positive (none when high equals low) → Candle direction

All other inputs remain at their defaults. On a PC, the default is on the left and the change example on the right; at smartphone width they appear in the same order from top to bottom.

Default settingsInpSign = Positive (none when high equals low)
Volume Quadrants default settings
Default: classified volume shown on the positive side.
View the screen in detail at full size
Volume Quadrants default settings (actual size)
Example of changed settingsInpSign = Candle direction
Volume Quadrants example of changed settings
Change example: signed by candle direction and also shown on the negative side.
View the screen in detail at full size
Volume Quadrants example of changed settings (actual size)

Published example: M1. This is an example to explain the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the included version has display settings for the brand text and QR code. The example with changed settings is not a set of recommended values. Details can be checked in the full-size view. Also check the vertical axis and units of the separate window. Except for products with a fixed scale, the scale changes with the settings and the displayed range.

2

How to read it in 30 seconds

Bar size

The absolute value is the current bar's tick volume.

Color classification

Divided into 4 groups by the changes of volume and True Range from the previous bar.

Bars with no histogram bar

If either is equal to the previous bar, the bar is not classified and no value is output.

3

What it measures

Combines the increases and decreases of volume and true range and shows them as bars in 4 colors.

Yellow-green, red

Bars where volume increased. Yellow-green if True Range also increased, red if it decreased.

Blue, gray

Bars where volume decreased. Blue if True Range increased, gray if it decreased.

True Range

A range that includes not only the high-low difference but also the gap from the previous close.

Choice of sign

By default, the value is positive if high>low. With Candle direction, it is positive if the close is at or above the open and negative if below. The color classification does not change.

4

Situations for reading the display

Read the default display

Indicator
The absolute value is the current bar's tick volume.
Cross-check
Check the candle and vertical axis for the same bar.
Check
First check Mode, the method and the period.
Caution
It is not a signal that shows a trading direction or a future price.

Compare by changing the settings

Indicator
Change example: signed by candle direction and also shown on the negative side.
Cross-check
Check the settings differences between the default screen and the change example.
Check
Compare on separate charts with the same timeframe and the same history.
Caution
Changing the method can change even the units.

Investigate blank or equal-value bars

Indicator
The first bar, and bars where volume or True Range equals that of the previous bar, are blank. With the default method, bars with high=low are also blank.
Cross-check
Check the start of the history and bars with 0 volume.
Check
Distinguish no value from the number 0.
Caution
An empty screen alone is not judged to be a malfunction.
5

Steps for checking the display

1

Apply with the defaults

Load history on the same symbol and timeframe, and first check the default settings.

2

Read the units and colors

The absolute value is the current bar's tick volume.

3

Change 1 condition at a time

Refer to the published change example and check how the inputs correspond to the display. For change examples with several conditions, comparing each condition separately lets you follow the differences.

4

Compare on closed bars

The value on the current bar changes. Compare numbers at the same past time.

6

Installation and checking the package contents

Included filePurpose / location
TRI_Volume_Quadrants.ex5The MT5 main file. Place it in MQL5/Indicators.

The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.

1

Extract the ZIP

Extract the ex5 main file rather than leaving it in the compressed file.

2

Open the data folder

In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.

3

Apply this product

Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.

4

Check the settings and display

First check with the default values. Changes and removal are done from the chart's 'Indicators List'.

Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.

7

Settings

There are 5 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.

Bar sign

English item name
Sign
Input name
InpSign
Default
Positive (none when high equals low)
Allowed range
Positive (none when high equals low)/Candle direction
Description
The default is the positive side only. With Candle, bars are split up and down by candle direction.

Show brand and QR

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Allowed range
true / false
Description
true shows the brand text and QR. When several products from the same medium are used on the same chart, the display is shared.

Brand position

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Allowed range
Top left / Bottom left / Bottom right / Top right
Description
The default is the lower left. Move it if displays overlap.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Allowed range
Integer (pixels)
Description
Horizontal margin from the reference corner. Negative numbers are treated as 0.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Allowed range
Integer (pixels)
Description
Vertical margin from the reference corner. Negative numbers are treated as 0.
8

Usage specifications

Current bar

Values on the unclosed bar change as price and tick volume update. Do not confuse them with closed bars.

Differences between history and data feeds

Tick volume differs by data provider, timeframe and history range. Do not directly compare values from different accounts or symbols.

Brand display

The packaged version has a function that shows Produced by Trilogy Inc. and a QR code linking to https://www.trgy.co.jp/. The display position and other details can be changed in additional settings. There is no account authentication.

For on-screen display only

The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.

9

Troubleshooting and usage notes

There are price bars but no histogram bars

The first bar, and bars where volume or True Range equals that of the previous bar, are blank. With the default method, bars with high=low are also blank.

Not all 4 colors are visible

If the condition is not met in the period you are viewing, that color does not appear. Gray bars are thinner than the other 3 colors.

The display is crowded

Use separate charts, or change the brand position and margins. Increase the height of the separate window, and also refer to the actual-size images.

If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.

10

Technical information and specification details

Definition of True Range

For the first bar, high−low. After that, max(high, previous close)−min(low, previous close).

Handling equal values

Increase and decrease are strict comparisons. Ties are not filled in with the previous color.