MT5 indicators← TRIX Plus product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

TRIX Plus

Builds the 1-bar rate of change of the price from one of several smoothing methods, and shows a selection of a signal, difference bars and cross marks on closed bars.

Indicator name: TRIX PlusMetaTrader 5Separate window

How to read the display

1Blue TRIX and orange signal2Choose the smoothing and the unit3Bars, marks and the comparison line are optional
Schematic diagram of how to read it. This is not an actual terminal screen.
1

Blue TRIX and orange signalIt is the change of the smoothed value as a ratio to the previous bar. The signal is an average of TRIX and is hidden when its period is 0.

2

Choose the smoothing and the unitYou can choose 3-stage EMA, TEMA, 2-stage SMMA + EMA, or T3. Percent is 100 times Fraction.

3

Bars, marks and the comparison line are optionalThe bars are TRIX − signal. Cross marks are on closed bars only. Specifying a 2nd period adds a gold comparison TRIX.

Display of calculated resultsMT5 onlyNot a buy or sell instruction
1

MT5 display and examples of changed settings

Compares the default settings and a settings change example on a screen with only this product applied.

Settings change example: these items are changed
Smoothing period / Period
InpPeriod
15 → 13
Smoothing method / Smoothing
InpSmoothing
EMA of EMA of EMA → SMMA, SMMA, then EMA
Rate-of-change unit / Unit
InpUnit
Percent → Fraction
Signal period / Signal Period (0 = off)
InpSignalPeriod
9 → 8
Difference bars / Show Histogram (TRIX minus Signal)
InpHistogram
false → true
Cross marks / Show Cross Marks
InpCrossMarks
false → true

All other inputs remain at their defaults. On a PC, the default is on the left and the change example on the right; at smartphone width they appear in the same order from top to bottom.

Default settingsInpPeriod = 15 / InpSmoothing = EMA of EMA of EMA / InpUnit = Percent / InpSignalPeriod = 9 / InpHistogram = false / InpCrossMarks = false
TRIX Plus default settings
Default settings. The change of the smoothed value as a ratio to the previous bar. The signal is an average of TRIX; with period 0 it is hidden.
View the screen in detail at full size
TRIX Plus default settings (full size)
Settings change exampleInpPeriod = 13 / InpSmoothing = SMMA, SMMA, then EMA / InpUnit = Fraction / InpSignalPeriod = 8 / InpHistogram = true / InpCrossMarks = true
TRIX Plus settings change example
Change example: Period = 13, Smoothing = SMMA, SMMA, then EMA, Unit = Fraction, Signal Period (0 = off) = 8, Show Histogram (TRIX minus Signal) = true, Show Cross Marks = true.
View the screen in detail at full size
TRIX Plus settings change example (full size)

Published example: M1. This is an example to explain the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the included version has display settings for the brand text and QR code. The example with changed settings is not a set of recommended values. Details can be checked in the full-size view. Also check the vertical axis and units of the separate window. Except for products with a fixed scale, the scale changes with the settings and the displayed range.

2

How to read it in 30 seconds

Blue TRIX and orange signal

It is the change of the smoothed value as a ratio to the previous bar. The signal is an average of TRIX and is hidden when its period is 0.

Choose the smoothing and the unit

You can choose 3-stage EMA, TEMA, 2-stage SMMA + EMA, or T3. Percent is 100 times Fraction.

Bars, marks and the comparison line are optional

The bars are TRIX − signal. Cross marks are on closed bars only. Specifying a 2nd period adds a gold comparison TRIX.

3

What it measures

Builds the 1-bar rate of change of the price from one of several smoothing methods, and shows a selection of a signal, difference bars and cross marks on closed bars.

How the calculation works

TRIX = u × (smoothed value(t) − smoothed value(t−1)) ÷ smoothed value(t−1). u is 100 for Percent and 1 for Fraction. If the previous value is 0, the result is 0. TEMA is 3EMA − 3EMA2 + EMA3 and differs from the 3-stage EMA itself. T3 uses 1+0.5×(Period−1) as its internal period and combines 6 stages of EMA with T3 Factor.

Conditions and exceptions

The SMMA method is shown once each stage has the history it needs, and the rate of change additionally needs the previous bar. With a signal period of 0, the bars and cross marks cannot be used. A mark is green when TRIX ≤ signal on the previous bar and TRIX is above it on that closed bar, and orange-red in the reverse case; it is drawn at the position of the signal. The line on the forming bar changes, but no mark is shown there.

4

Situations for reading the display

Read lines, bars and colors separately

Indicator
It is the change of the smoothed value as a ratio to the previous bar. The signal is an average of TRIX and is hidden when its period is 0.
Cross-check
Cross-check the values and settings at the same time point.
Check
Read separately which value is compared with what to give each color.
Caution
Colors and marks alone do not determine the trading direction.

Compare setting differences

Indicator
Change example: Period = 13, Smoothing = SMMA, SMMA, then EMA, Unit = Fraction, Signal Period (0 = off) = 8, Show Histogram (TRIX minus Signal) = true, Show Cross Marks = true.
Cross-check
Use the same symbol, timeframe and history.
Check
Keep the conditions the same, and check the relation between the changed inputs and the display.
Caution
The published settings are not recommended values.

Check blanks and flat sections

Indicator
The SMMA method is shown once each stage has the history it needs, and the rate of change additionally needs the previous bar. With a signal period of 0, the bars and cross marks cannot be used. A mark is green when TRIX ≤ signal on the previous bar and TRIX is above it on that closed bar, and orange-red in the reverse case; it is drawn at the position of the signal. The line on the forming bar changes, but no mark is shown there.
Cross-check
Check the required history and whether the display is enabled or disabled.
Check
Distinguish no value from a value of 0.
Caution
If it does not update even when the conditions are met, check the connection and the inputs.
5

Steps for checking the display

1

Apply with the defaults

Load the history in MT5, and first apply only this product to the chart.

2

Check the role of the display

It is the change of the smoothed value as a ratio to the previous bar. The signal is an average of TRIX and is hidden when its period is 0.

3

Comparing settings

Put the default and the change example on separate charts, and compare them with the same symbol, timeframe and history.

4

Distinguish the forming bar

The value of the forming bar changes with price updates. Read it separately from closed bars.

6

Installation and checking the package contents

Included filePurpose / location
TRI_TRIX_Plus.ex5The MT5 main file. Place it in MQL5/Indicators.

The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.

1

Extract the ZIP

Extract the ex5 main file rather than leaving it in the compressed file.

2

Open the data folder

In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.

3

Apply this product

Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.

4

Check the settings and display

First check with the default values. Changes and removal are done from the chart's 'Indicators List'.

Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.

7

Settings

There are 14 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.

Smoothing period

English item name
Period
Input name
InpPeriod
Default
15
Allowed range
Integer 1–1000
Description
Used for the selected smoothing.

Smoothing method

English item name
Smoothing
Input name
InpSmoothing
Default
EMA of EMA of EMA
Allowed range
3-stage EMA / TEMA / 2-stage SMMA + EMA / T3
Description
The initial values, the number of bars needed for preparation, and the response differ by method.

T3 factor

English item name
T3 Volume Factor
Input name
InpT3Factor
Default
0.7
Allowed range
0 to 1
Description
The combining factor for the T3 method. Set it within the range even for other methods.

Calculation price

English item name
Price
Input name
InpPrice
Default
Close
Allowed range
Close / Open / High / Low / Median / Typical / Weighted
Description
Median=(H+L)/2、Typical=(H+L+C)/3、Weighted=(H+L+2C)/4。

Rate-of-change unit

English item name
Unit
Input name
InpUnit
Default
Percent
Allowed range
Percent / Fraction
Description
Percent multiplies the ratio by 100.

Signal period

English item name
Signal Period (0 = off)
Input name
InpSignalPeriod
Default
9
Allowed range
Integer 0–1000
Description
0 disables it. 1 or more when using the bars or marks.

Signal method

English item name
Signal Method
Input name
InpSignalMethod
Default
EMA
Allowed range
SMA / EMA / SMMA / LWMA
Description
Averages TRIX.

Difference bars

English item name
Show Histogram (TRIX minus Signal)
Input name
InpHistogram
Default
false
Allowed range
true / false
Description
Shows TRIX − signal as blue-gray bars.

Cross marks

English item name
Show Cross Marks
Input name
InpCrossMarks
Default
false
Allowed range
true / false
Description
Shows crosses on closed bars with green and orange-red marks. These are not trading instructions.

2nd period

English item name
Second TRIX Period (0 = off)
Input name
InpSecondPeriod
Default
0
Allowed range
Integer 0–1000
Description
0 disables it. If positive, a gold comparison line is added with the same method, price and unit.

Brand and QR

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Allowed range
true / false
Description
Displayed with true. Calculated values do not change.

Brand position

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Allowed range
Top left / Bottom left / Bottom right / Top right
Description
The default is bottom left.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0.
8

Usage specifications

Display only

It does not place, modify or close orders. There are no notifications or emails either.

History and initial values

Values on the forming bar are updated. Differences in data provider, symbol, timeframe and history start position affect the values and initial values.

Display units

Check the scale of the separate window. Do not treat the state bar heights, price differences and ratio displays as the same scale.

Brand display

Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.

For on-screen display only

The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.

9

Troubleshooting and usage notes

No display / blank partway

The SMMA method is shown once each stage has the history it needs, and the rate of change additionally needs the previous bar. With a signal period of 0, the bars and cross marks cannot be used. A mark is green when TRIX ≤ signal on the previous bar and TRIX is above it on that closed bar, and orange-red in the reverse case; it is drawn at the position of the signal. The line on the forming bar changes, but no mark is shown there.

The input is not accepted

Check the ranges and combinations in the settings. Inputs for methods not in use must also be within the allowed range.

Values differ from those with other settings

TRIX = u × (smoothed value(t) − smoothed value(t−1)) ÷ smoothed value(t−1). u is 100 for Percent and 1 for Fraction. If the previous value is 0, the result is 0. TEMA is 3EMA − 3EMA2 + EMA3 and differs from the 3-stage EMA itself. T3 uses 1+0.5×(Period−1) as its internal period and combines 6 stages of EMA with T3 Factor.

Displays overlap

Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.

If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.

10

Technical information and specification details

Calculation and reference range

TRIX = u × (smoothed value(t) − smoothed value(t−1)) ÷ smoothed value(t−1). u is 100 for Percent and 1 for Fraction. If the previous value is 0, the result is 0. TEMA is 3EMA − 3EMA2 + EMA3 and differs from the 3-stage EMA itself. T3 uses 1+0.5×(Period−1) as its internal period and combines 6 stages of EMA with T3 Factor.

Handling of initial values and exceptions

The SMMA method is shown once each stage has the history it needs, and the rate of change additionally needs the previous bar. With a signal period of 0, the bars and cross marks cannot be used. A mark is green when TRIX ≤ signal on the previous bar and TRIX is above it on that closed bar, and orange-red in the reverse case; it is drawn at the position of the signal. The line on the forming bar changes, but no mark is shown there.

Package contents and dependencies

Only MT5 itself and this manual. Account authentication, external indicators and DLLs are not required.