MT5 indicators← Stochastic Cross CCI Filter Arrows product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

Stochastic Cross CCI Filter Arrows

Combines Stochastic crosses with the direction of 2 CCIs, long and short, and a selected additional condition, and shows arrows.

Indicator name: Stochastic Cross CCI Filter ArrowsMetaTrader 5Main chart

How to read the display

1A cross alone does not produce a mark2The default is the Entry CCI range3The other method compares band widths
Schematic diagram of how to read it. This is not an actual terminal screen.
1

A cross alone does not produce a markThe sign of Trend CCI and the change in Entry CCI are also checked.

2

The default is the Entry CCI rangeUp is above −100 and below 200; down is above −200 and below 100.

3

The other method compares band widthsBands Wider is when the band width is wider than the Keltner side. It is not a squeeze condition.

Record of conditions metMT5 onlyNot a trading instruction
1

MT5 display and examples of changed settings

Compares the default settings and a settings change example on a screen with only this product applied.

Settings change example: these items are changed
Main period / %K Period
InpKPeriod
5 → 9
Signal method / Signal Method
InpSignalMethod
EMA → SMA
Stochastic price / Price Field
InpPriceField
Low/High → Close/Close
Trend CCI period / Trend CCI Period
InpTrendCCI
50 → 30
Entry CCI period / Entry CCI Period
InpEntryCCI
14 → 10

All other inputs remain at their defaults. On a PC, the default is on the left and the change example on the right; at smartphone width they appear in the same order from top to bottom.

Default settingsInpKPeriod = 5 / InpSignalMethod = EMA / InpPriceField = Low/High / InpTrendCCI = 50 / InpEntryCCI = 14
Stochastic Cross CCI Filter Arrows default settings
Default settings. It also checks the sign of Trend CCI and the change in Entry CCI.
View the screen in detail at full size
Stochastic Cross CCI Filter Arrows default settings (actual size)
Example of changed settingsInpKPeriod = 9 / InpSignalMethod = SMA / InpPriceField = Close/Close / InpTrendCCI = 30 / InpEntryCCI = 10
Stochastic Cross CCI Filter Arrows example of changed settings
Example change: %K Period = 9, Signal Method = SMA, Price Field = Close/Close, Trend CCI Period = 30, Entry CCI Period = 10.
View the screen in detail at full size
Stochastic Cross CCI Filter Arrows example of changed settings (actual size)

Example shown: M1. This is an example for explaining the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the packaged version has display settings for the brand text and the QR code. The settings change example is not a recommended value. Details can be checked in the full-size view. Please also check the price scale of the main chart and the positions of the candlesticks.

2

How to read it in 30 seconds

A cross alone does not produce a mark

The sign of Trend CCI and the change in Entry CCI are also checked.

The default is the Entry CCI range

Up is above −100 and below 200; down is above −200 and below 100.

The other method compares band widths

Bands Wider is when the band width is wider than the Keltner side. It is not a squeeze condition.

3

What it measures

Combines Stochastic crosses with the direction of 2 CCIs, long and short, and a selected additional condition, and shows arrows.

How the calculation works

Main is 100×Σ(close − lowest low in the period)÷Σ(highest high in the period − lowest low in the period). Σ covers Slowing bars, which differs from the method that takes a simple average of the ratios. If the sum of the denominator is 0, the value is 100. The first Main requires K+Slowing−1 bars of history. Signal is a moving average of Main. EMA starts from the first Main; SMA, SMMA and LWMA start once D bars are available. Up is Main strictly crossing above Signal, Trend CCI>0, and Entry CCI rising from the previous bar. Down is a strict cross below, Trend CCI<0, and Entry CCI falling. With Entry Range, up additionally requires −100<Entry CCI<200, and down −200<Entry CCI<100. With Bands Wider, instead of this range condition, Deviation×population standard deviation of the close÷(Factor×ATR)>1 is used. The CCI price is Typical.

Conditions and exceptions

ATR is the simple average of True Range over the specified period. If the denominator of the band width is 0, the Bands Wider condition is not met. A CCI mean deviation of 0 gives CCI=0, which does not satisfy the strict sign condition of Trend. Even when a method is not in use, keep the band and ATR inputs within the allowed range. The change example shown is also Entry Range, not a capture example of Bands Wider. The check is made once each series and the required previous bar are available.

4

Situations for reading the display

Reading the line and mark conditions

Indicator
The sign of Trend CCI and the change in Entry CCI are also checked.
Cross-check
Cross-check the prices and settings at the same time.
Check
Check which line is larger, how equal values are handled, and the relationship with the previous bar.
Caution
Arrows and dots are not recommendations to place or close orders.

Compare setting differences

Indicator
Example change: %K Period = 9, Signal Method = SMA, Price Field = Close/Close, Trend CCI Period = 30, Entry CCI Period = 10.
Cross-check
Use the same symbol, timeframe and history.
Check
Look at how the changed setting relates to the increase or decrease and the position of the marks.
Caution
The published settings are not recommended values.

Reading intervals without marks

Indicator
ATR is the simple average of True Range over the specified period. If the denominator of the band width is 0, the Bands Wider condition is not met. A CCI mean deviation of 0 gives CCI=0, which does not satisfy the strict sign condition of Trend. Even when a method is not in use, keep the band and ATR inputs within the allowed range. The change example shown is also Entry Range, not a capture example of Bands Wider. The check is made once each series and the required previous bar are available.
Cross-check
Check the required history and whether the conditions are met.
Check
Do not treat the absence of marks as the calculation having stopped.
Caution
Nothing may be displayed during periods when the conditions are not met.
5

Steps for checking the display

1

Apply with the defaults

Load the history in MT5, and first apply only this product to the chart.

2

Check the role of the display

The sign of Trend CCI and the change in Entry CCI are also checked.

3

Comparing settings

Put the default and the change example on separate charts, with the same symbol, timeframe and history.

4

Distinguish the forming bar

Closed Bars Only defaults to true. With false, marks on the forming bar can change, so distinguish them from the record on closed bars.

6

Installation and checking the package contents

Included filePurpose / location
TRI_Stochastic_Cross_CCI_Filter_Arrows.ex5The MT5 main file. Place it in MQL5/Indicators.

The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.

1

Extract the ZIP

Extract the ex5 main file rather than leaving it in the compressed file.

2

Open the data folder

In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.

3

Apply this product

Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.

4

Check the settings and display

First check with the default values. Changes and removal are done from the chart's 'Indicators List'.

Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.

7

Settings

There are 17 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.

Main period

English item name
%K Period
Input name
InpKPeriod
Default
5
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Signal period

English item name
%D Period
Input name
InpDPeriod
Default
3
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Bars summed for the numerator and denominator

English item name
Slowing
Input name
InpSlowing
Default
3
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Signal method

English item name
Signal Method
Input name
InpSignalMethod
Default
EMA
Allowed range
SMA / EMA / SMMA / LWMA
Description
Simple, exponential, smoothed or linear weighted average. EMA starts from the first valid value; the other methods start once a period's worth of valid values is available.

Stochastic price

English item name
Price Field
Input name
InpPriceField
Default
Low/High
Allowed range
Low/High / Close/Close
Description
Low/High uses the highest high and lowest low in the period, and Close/Close uses the highest close and lowest close. The numerator price is the close in both cases.

Trend CCI period

English item name
Trend CCI Period
Input name
InpTrendCCI
Default
50
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Entry CCI period

English item name
Entry CCI Period
Input name
InpEntryCCI
Default
14
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Additional conditions

English item name
Filter
Input name
InpFilter
Default
Entry CCI Range
Allowed range
Entry Range/Bands Wider
Description
Selects the CCI range condition or a band-width ratio>1.

Band period

English item name
Bands Period
Input name
InpBandsPeriod
Default
20
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

Standard deviation multiplier

English item name
Bands Deviation
Input name
InpBandsDeviation
Default
2
Allowed range
Greater than 0 and up to 10
Description
Multiplied by the population standard deviation of the close in Bands Wider.

ATR period

English item name
Keltner ATR Period
Input name
InpKeltnerPeriod
Default
20
Allowed range
Integer 1–500
Description
The number of bars used in the calculation.

ATR multiplier

English item name
Keltner Factor
Input name
InpKeltnerFactor
Default
1.5
Allowed range
Greater than 0 and up to 10
Description
The multiplier applied to ATR in Bands Wider.

Place marks on closed bars only

English item name
Closed Bars Only
Input name
InpClosedBarsOnly
Default
true
Allowed range
true / false
Description
true does not show marks on the latest forming bar. With false, marks on the forming bar may appear, disappear or move. For products with lines, the latest value of the lines is updated.

Brand and QR

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Allowed range
true / false
Description
Displayed with true. Calculated values do not change.

Brand position

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Allowed range
Top left / Bottom left / Bottom right / Top right
Description
The default is bottom left.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.
8

Usage specifications

Display only

It does not place, modify or close orders. There are no notifications or emails either.

Closed bars and history

Even with Closed Bars Only=true, it is not guaranteed to stay unchanged through corrections or additions to the history or changes of the start position. Products that have lines update the line on the current bar.

Mark positions

Up arrows are drawn 10 pixels below the low, and down arrows 10 pixels above the high. This is not a fixed distance in price.

Brand display

Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.

For on-screen display only

The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.

9

Troubleshooting and usage notes

No marks, or blanks in the middle

ATR is the simple average of True Range over the specified period. If the denominator of the band width is 0, the Bands Wider condition is not met. A CCI mean deviation of 0 gives CCI=0, which does not satisfy the strict sign condition of Trend. Even when a method is not in use, keep the band and ATR inputs within the allowed range. The change example shown is also Entry Range, not a capture example of Bands Wider. The check is made once each series and the required previous bar are available.

The input is not accepted

Check the ranges and combinations in the settings. Keep the inputs for unused methods within range as well.

The marks differ from other cross indicators

Main is 100×Σ(close − lowest low in the period)÷Σ(highest high in the period − lowest low in the period). Σ covers Slowing bars, which differs from the method that takes a simple average of the ratios. If the sum of the denominator is 0, the value is 100. The first Main requires K+Slowing−1 bars of history. Signal is a moving average of Main. EMA starts from the first Main; SMA, SMMA and LWMA start once D bars are available. Up is Main strictly crossing above Signal, Trend CCI>0, and Entry CCI rising from the previous bar. Down is a strict cross below, Trend CCI<0, and Entry CCI falling. With Entry Range, up additionally requires −100<Entry CCI<200, and down −200<Entry CCI<100. With Bands Wider, instead of this range condition, Deviation×population standard deviation of the close÷(Factor×ATR)>1 is used. The CCI price is Typical.

Displays overlap

Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.

If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.

10

Technical information and specification details

Calculation and reference range

Main is 100×Σ(close − lowest low in the period)÷Σ(highest high in the period − lowest low in the period). Σ covers Slowing bars, which differs from the method that takes a simple average of the ratios. If the sum of the denominator is 0, the value is 100. The first Main requires K+Slowing−1 bars of history. Signal is a moving average of Main. EMA starts from the first Main; SMA, SMMA and LWMA start once D bars are available. Up is Main strictly crossing above Signal, Trend CCI>0, and Entry CCI rising from the previous bar. Down is a strict cross below, Trend CCI<0, and Entry CCI falling. With Entry Range, up additionally requires −100<Entry CCI<200, and down −200<Entry CCI<100. With Bands Wider, instead of this range condition, Deviation×population standard deviation of the close÷(Factor×ATR)>1 is used. The CCI price is Typical.

Initial values and exceptions

ATR is the simple average of True Range over the specified period. If the denominator of the band width is 0, the Bands Wider condition is not met. A CCI mean deviation of 0 gives CCI=0, which does not satisfy the strict sign condition of Trend. Even when a method is not in use, keep the band and ATR inputs within the allowed range. The change example shown is also Entry Range, not a capture example of Bands Wider. The check is made once each series and the required previous bar are available.

Package contents and dependencies