Compares both the high and the low
+1 if both are higher than on the previous bar, −1 if both are lower.
Counts bars where both the high and the low rose as +1, and bars where both fell as −1.
Compares both the high and the low+1 if both are higher than on the previous bar, −1 if both are lower.
Other bars are 0A new extreme on only one side, inside and outside bars, and equal values do not change the count.
Tell the cumulative total from the recent sumThe default is the cumulative total from the start of the history. Rolling Sum counts only the most recent bars.
Compares the default settings and a settings change example on a screen with only this product applied.
Published example: M1. This is an example to explain the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the included version has display settings for the brand text and QR code. The example with changed settings is not a set of recommended values. Details can be checked in the full-size view. Also check the vertical axis and units of the separate window. Except for products with a fixed scale, the scale changes with the settings and the displayed range.
+1 if both are higher than on the previous bar, −1 if both are lower.
A new extreme on only one side, inside and outside bars, and equal values do not change the count.
The default is the cumulative total from the start of the history. Rolling Sum counts only the most recent bars.
Counts bars where both the high and the low rose as +1, and bars where both fell as −1.
Each bar's change is classified as +1, −1 or 0. Cumulative sets the oldest bar to 0 and adds up the changes after it. Rolling Sum is the sum of the changes over the last Rolling Window bars. Because the previous bar is needed, the recent sum is displayed once the first Window+1 bars are available.
The level of the cumulative total changes with where the history starts, so its absolute value or 0 is not used as a fixed market judgment. The recent sum is also blank early in the history. The size of the price change is not counted; every bar is 1 vote. If the high or low of the forming bar moves, the classification also changes.
Load the history in MT5, and first apply only this product to the chart.
+1 if both are higher than on the previous bar, −1 if both are lower.
Put the default and the change example on separate charts, and compare them with the same symbol, timeframe and history.
The value of the forming bar changes with price updates. Read it separately from closed bars.
| Included file | Purpose / location |
|---|---|
| TRI_HH_LL_Count.ex5 | The MT5 main file. Place it in MQL5/Indicators. |
The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.
Extract the ex5 main file rather than leaving it in the compressed file.
In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.
Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.
First check with the default values. Changes and removal are done from the chart's 'Indicators List'.
Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.
There are 6 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.
InpModeInpWindowInpTriBrandShowInpTriBrandCornerInpTriBrandXInpTriBrandYIt does not place, modify or close orders. There are no notifications or emails either.
Values on the forming bar are updated. Differences in data provider, symbol, timeframe and history start position affect the values and initial values.
Check the scale of the separate window. Do not treat the state bar heights, price differences and ratio displays as the same scale.
Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.
The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.
The level of the cumulative total changes with where the history starts, so its absolute value or 0 is not used as a fixed market judgment. The recent sum is also blank early in the history. The size of the price change is not counted; every bar is 1 vote. If the high or low of the forming bar moves, the classification also changes.
Check the ranges and combinations in the settings. Inputs for methods not in use must also be within the allowed range.
Each bar's change is classified as +1, −1 or 0. Cumulative sets the oldest bar to 0 and adds up the changes after it. Rolling Sum is the sum of the changes over the last Rolling Window bars. Because the previous bar is needed, the recent sum is displayed once the first Window+1 bars are available.
Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.
If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.
Each bar's change is classified as +1, −1 or 0. Cumulative sets the oldest bar to 0 and adds up the changes after it. Rolling Sum is the sum of the changes over the last Rolling Window bars. Because the previous bar is needed, the recent sum is displayed once the first Window+1 bars are available.
The level of the cumulative total changes with where the history starts, so its absolute value or 0 is not used as a fixed market judgment. The recent sum is also blank early in the history. The size of the price change is not counted; every bar is 1 vote. If the high or low of the forming bar moves, the classification also changes.
Only MT5 itself and this manual. Account authentication, external indicators and DLLs are not required.