MT5 indicators← Fixed Filter Oscillator product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

Fixed Filter Oscillator

Draws price differences and band components from filters that multiply the close by fixed coefficients. Of the five modes, only the two difference modes color the bars by whether the value increased from the previous bar.

Components and differences of fixed-coefficient filtersMetaTrader 5Separate windowSite edition, no account authentication

Components and differences of fixed-coefficient filters

STEP 1A finite number of closes
STEP 2Weighted sum with fixed coefficients
STEP 3Line or bars colored by increase/decrease
1

3 line modesPCCI, PCCI Long and RBCI are blue lines.

2

2 bar modesIn RBCI Difference and KG Difference, a bar is blue if it increased from the previous bar and red if it is unchanged or decreased.

3

Separate from the signA red bar can have a positive value and a blue bar can have a negative value. The color is not a comparison with 0.

The figure explains the processDisplay only, no order functionsCreated by Trilogy
1

Checking the display

Settings change example: Mode: PCCI → RBCI Difference

Everything not listed stays at the default. On a PC the order is 'Default, Change example' from left, and on a smartphone from top. The change example is not a set of recommended values.

Default settings
Fixed Filter Oscillator default screen
Defaults: The blue line of PCCI. The vertical axis is the size of the price difference.
Settings change example
Fixed Filter Oscillator change example
Changed to RBCI Difference. Bars are blue for an increase and red for unchanged or decreased; the sign and the color do not necessarily match.

The published images are display examples from before the brand display was added. The product has display settings for the brand text and QR code, but the screen with the brand display has not yet been verified. The timeframe shown in the image does not indicate how often this appears on that timeframe in practice. Marks at the edges may be cut off outside the screen.

Check all inputs of the change example

Mode = RBCI Difference (40-bar minus 73-bar)。

The 4 brand display items are not included in the capture.

2

30-second guide

3 line modes

PCCI, PCCI Long and RBCI are blue lines.

2 bar modes

In RBCI Difference and KG Difference, a bar is blue if it increased from the previous bar and red if it is unchanged or decreased.

Separate from the sign

A red bar can have a positive value and a blue bar can have a negative value. The color is not a comparison with 0.

3

What it measures

Draws price differences and band components from filters that multiply the close by fixed coefficients. Of the five modes, only the two difference modes color the bars by whether the value increased from the previous bar.

PCCI

Midpoint of high and low − 40-bar filter of the close. PCCI Long is close − 106-bar filter of the close.

RBCI

The sign-reversed value of a 56-bar band filter of the close. There is no input to change the period.

The two differences

RBCI Difference is 40-bar filter − 73-bar filter. KG Difference is 56-bar filter − 62-bar filter. The 56-bar table of KG is separate from the 56-bar table of RBCI.

Waiting at the start

The required bars are 40, 106, 56, 73 and 62 in that order. The first value in the difference modes has no previous bar to compare, so it is placed on the red side.

4

Reading scenarios

When you want to classify the display

PCCI, PCCI Long and RBCI are blue lines.

When you want to switch conditions and compare

Use the same symbol, timeframe and history, and first change only one input. Use separate charts for comparison, and check the Mode and vertical axis of each screen.

The display differs from what you expected

If nothing is shown, check whether the number of bars required by the selected mode has been loaded.

This display alone does not decide whether to trade. The colors, lines and arrows represent the calculation conditions in this manual; they are not a forecast of future price movement or an instruction to buy or sell.

5

Check procedure

1

Start from the defaults

At first, do not change the inputs; cross-check the colors and display location against the default screen above.

2

Distinguish the timing of bars

The value of the latest forming bar changes. There is no Closed Bars Only input. Read it separately from bars after they close.

3

Change only the target condition

Mode: PCCI → RBCI Difference. Comparison images may include multiple changes.

4

Check values and units

The angle of lines and visible differences change with the screen zoom. Check the settings together with the price scale and the vertical axis of the separate window.

6

Installation and package contents

ZIP contentsLocation / role
TRI_Fixed_Filter_Oscillator.ex5MQL5/Indicators in MT5. Only 1 item: the indicator itself.

The manual opens on the product's own page on the site. The ZIP does not include the manual or source code. It is for MT5 only and cannot be used in MT4. The site edition has no account authentication or license file settings.

1

Extract the ZIP

Prepare the extracted EX5. Do not place it while it is still compressed.

2

To the MT5 data folder

Place the EX5 in MQL5/Indicators via 'File → Open Data Folder'.

3

Apply to a chart

Refresh the Navigator or restart the terminal, and apply it to the target chart. DLL permission is not required.

4

Change / remove

Change the settings or remove it from the chart's 'Indicators List'. Enabling automated trading is not required.

7

Settings

1 product-specific item and 4 brand display items, 5 items in total. English names are based on the input definitions. Enter numbers in half-width characters. Keep inputs that the mode does not use within range as well.

Mode

English item name
Mode
Input name
InpMode
Default
PCCI (median minus 40-bar filter)
Options / range
PCCI (median minus 40-bar filter) / PCCI Long (close minus 106-bar filter) / RBCI (56-bar band filter) / RBCI Difference (40-bar minus 73-bar) / KG Difference (56-bar minus 62-bar)
Meaning and notes
Selects the fixed coefficients and the drawing style. Periods and coefficients cannot be entered manually.

Brand / QR display

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Options / range
true / false
Meaning and notes
This is a display-only setting. It does not change calculation results. If another product on the same chart has the display enabled, the shared display remains.

Brand corner

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Options / range
Top left / Bottom left / Bottom right / Top right
Meaning and notes
The chart corner where the brand text and QR code are placed.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Options / range
Corrected to 0–4000 px
Meaning and notes
Horizontal distance from the selected corner. Negative values are corrected to 0, and values above 4000 to 4000.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Options / range
Corrected to 0–4000 px
Meaning and notes
Vertical distance from the selected corner. If the screen is narrow, adjust the position or the value.
8

Usage specifications

Forming bar

The value of the latest forming bar changes. There is no Closed Bars Only input. Read it separately from bars after they close.

History and recalculation

Settings changes, additions to or corrections of the history, and reloading redo the calculation. This is not a guarantee that "closed bars never change under any circumstances".

Brand display

A common display is shared among products of the same medium on the same chart. If several are loaded, the settings of the registration that enabled the display first are used, so changing one may not change the appearance.

For on-screen display only

This product does not place orders or trade automatically. It does not guarantee accuracy as a trading signal or profits.

9

Troubleshooting

Points that are easy to get confused about in this product

If nothing is shown, check whether the number of bars required by the selected mode has been loaded.

No display

Check whether the required number of history bars is available, whether the forming bar is hidden, and the input ranges and mode. Also check the terminal's Experts tab for input errors.

The display does not update

Check the price feed and the connection status. Changing settings for an unused mode does not change the display.

Looks different from the image

The appearance changes with the symbol, history, timeframe, inputs and scale. Even when compared with the full-size image, the marks are not necessarily at the same positions or of the same count.

10

Specification details

Specification note 1

A finite-length FIR. It is not a filter that carries recursive state forward indefinitely.

Specification note 2

The latest bar changes. Do not compare amplitudes of different symbols or price digits directly as the same strength.

Verified scope

The published images and values were checked with the product before the brand display was added. The screen display of the product with the brand display has not yet been verified. Whether the values match other indicators with the same name, the Data Window display, and behavior with long histories or with symbols that have different price digits have not been verified.

Products with a price selection

Median = (high + low)/2, Typical = (high + low + close)/3, Weighted = (high + low + close×2)/4. The unit of periods is the number of chart bars.