MT5 indicators← CCI Force Agreement product page日本語の取扱説明書

This product is in preparation for release. Product files are not yet distributed; the manual is published so that you can review its content. This manual is an English translation of the Japanese manual. Images (screens and figures) are not translated and may contain Japanese text or earlier names.

For Trilogy users

CCI Force Agreement

Shows as green +1 and red −1 bars only the bars on which CCI and Force have the same sign and their product is at or above Level.

Indicator name: CCI Force AgreementMetaTrader 5Separate window

How to read the display

1The default image is blank because the condition is not met2Green: both positive; red: both negative3Bars appear in the change example
Schematic diagram of how to read it. This is not an actual terminal screen.
1

The default image is blank because the condition is not metIn this captured range, no bar meets Level 34, so no bars appear. This does not indicate a malfunction.

2

Green: both positive; red: both negativeDraws only bars on which the signs of CCI and Force agree and the product is at or above Level.

3

Bars appear in the change exampleThis is an example with Level 5, period 13, close and EMA. It is a display example, not a recommended setting.

Display of calculated resultsMT5 onlyNot a buy or sell instruction
1

MT5 display and examples of changed settings

Compares the default settings and a settings change example on a screen with only this product applied.

Settings change example: these items are changed
Common CCI and Force period / CCI and Force Period
InpPeriod
5 → 13
Display lower limit of the product / Level (CCI x Force)
InpLevel
34 → 5
Common calculation price / Price
InpPrice
Weighted → Close
Force MA method / Force MA Method
InpForceMethod
LWMA → EMA

All other inputs remain at their defaults. On a PC, the default is on the left and the change example on the right; at smartphone width they appear in the same order from top to bottom.

Default settingsInpPeriod = 5 / InpLevel = 34 / InpPrice = Weighted / InpForceMethod = LWMA
CCI Force Agreement default settings
Default settings. In this captured range, no bar meets Level 34, so no bars appear. This does not indicate a malfunction.
View the screen in detail at full size
CCI Force Agreement default settings (actual size)
Settings change exampleInpPeriod = 13 / InpLevel = 5 / InpPrice = Close / InpForceMethod = EMA
CCI Force Agreement settings change example
Change example: CCI and Force Period = 13, Level (CCI x Force) = 5, Price = Close, Force MA Method = EMA.
View the screen in detail at full size
CCI Force Agreement settings change example (actual size)

Published example: M1. This is an example to explain the display. The published images are screens from before the brand display was added. The calculation and drawing conditions are the same, and the included version has display settings for the brand text and QR code. The example with changed settings is not a set of recommended values. Details can be checked in the full-size view. Also check the vertical axis and units of the separate window. Except for products with a fixed scale, the scale changes with the settings and the displayed range.

2

How to read it in 30 seconds

The default image is blank because the condition is not met

In this captured range, no bar meets Level 34, so no bars appear. This does not indicate a malfunction.

Green: both positive; red: both negative

Draws only bars on which the signs of CCI and Force agree and the product is at or above Level.

Bars appear in the change example

This is an example with Level 5, period 13, close and EMA. It is a display example, not a recommended setting.

3

What it measures

Shows as green +1 and red −1 bars only the bars on which CCI and Force have the same sign and their product is at or above Level.

How the calculation works

CCI of the selected price=(price−period average)/(0.015×mean absolute deviation). If the deviation is 0, CCI=0. Force=(current value−previous value of the MA of the selected price)×tick volume of the current bar. If CCI×Force>=Level and both are strictly positive, +1; if both are strictly negative, −1. Otherwise there is no value; it does not draw a bar of 0.

Conditions and exceptions

Level is neither a level of CCI itself nor pips; it is the lower limit of the product of CCI and Force. It depends on the unit and size of price changes and on tick volume, so the same value does not mean the same strength across symbols, data feeds or timeframes. Changing only the displayed digits does not change the formula. Even if Level is lowered, the display is blank when the signs disagree or one side is 0, and nothing is drawn when tick volume is 0. The CCI period and the MA up to the previous bar are needed, and on the forming bar the bars change with price and volume. Check the required history and inputs, and distinguish a blank from a calculation error.

4

Situations for reading the display

Read lines, bars and colors separately

Indicator
In this captured range, no bar meets Level 34, so no bars appear. This does not indicate a malfunction.
Cross-check
Cross-check the values and settings at the same time point.
Check
Read separately which value is compared with what to give each color.
Caution
Colors and marks alone do not determine the trading direction.

Compare setting differences

Indicator
Change example: CCI and Force Period = 13, Level (CCI x Force) = 5, Price = Close, Force MA Method = EMA.
Cross-check
Use the same symbol, timeframe and history.
Check
Keep the conditions the same, and check the relation between the changed inputs and the display.
Caution
The published settings are not recommended values.

Check blanks and flat sections

Indicator
Level is neither a level of CCI itself nor pips; it is the lower limit of the product of CCI and Force. It depends on the unit and size of price changes and on tick volume, so the same value does not mean the same strength across symbols, data feeds or timeframes. Changing only the displayed digits does not change the formula. Even if Level is lowered, the display is blank when the signs disagree or one side is 0, and nothing is drawn when tick volume is 0. The CCI period and the MA up to the previous bar are needed, and on the forming bar the bars change with price and volume. Check the required history and inputs, and distinguish a blank from a calculation error.
Cross-check
Check the required history and whether the display is enabled or disabled.
Check
Distinguish no value from a value of 0.
Caution
If it does not update even when the conditions are met, check the connection and the inputs.
5

Steps for checking the display

1

Apply with the defaults

Load the history in MT5, and first apply only this product to the chart.

2

Check the role of the display

In this captured range, no bar meets Level 34, so no bars appear. This does not indicate a malfunction.

3

Comparing settings

Put the default and the change example on separate charts, and compare them with the same symbol, timeframe and history.

4

Distinguish the forming bar

The value of the forming bar changes with price updates. Read it separately from closed bars.

6

Installation and checking the package contents

Included filePurpose / location
TRI_CCI_Force_Agreement.ex5The MT5 main file. Place it in MQL5/Indicators.

The ZIP contains only 1 item, the main file. The manual is opened from the product page on the site. Source code is not included. MT5 only; registration, account authentication and placing a license file are not required. Use it without changing the file name.

1

Extract the ZIP

Extract the ex5 main file rather than leaving it in the compressed file.

2

Open the data folder

In MT5, open MQL5/Indicators from 'File → Open Data Folder' and place the included ex5 there.

3

Apply this product

Refresh the Navigator or restart MT5, and apply it to the target chart. When comparing different settings, using separate charts makes checking easier.

4

Check the settings and display

First check with the default values. Changes and removal are done from the chart's 'Indicators List'.

Using this product does not require allowing DLLs. When removed, this product's drawings are cleared.

7

Settings

There are 8 inputs. Change them on the Inputs tab of the properties. The English item names and input names defined in the source are shown together.

Common CCI and Force period

English item name
CCI and Force Period
Input name
InpPeriod
Default
5
Allowed range
Integer 2–500
Description
Period used for CCI and the price MA.

Display lower limit of the product

English item name
Level (CCI x Force)
Input name
InpLevel
Default
34
Allowed range
0 to 1000000
Description
Shows only bars where CCI×Force is at or above this value and both have the same sign.

Shared calculation price

English item name
Price
Input name
InpPrice
Default
Weighted
Allowed range
Close / Open / High / Low / Median / Typical / Weighted
Description
Close / open / high / low / (high+low)/2 / (high+low+close)/3 / (high+low+close×2)/4.

Force MA method

English item name
Force MA Method
Input name
InpForceMethod
Default
LWMA
Allowed range
SMA / EMA / SMMA / LWMA
Description
Averages the price, then multiplies the difference from the previous bar by tick volume. It is not a method that averages Force itself.

Brand and QR

English item name
Show Trilogy brand and QR code
Input name
InpTriBrandShow
Default
true
Allowed range
true / false
Description
Displayed with true. Calculated values do not change.

Brand position

English item name
Brand position (chart corner)
Input name
InpTriBrandCorner
Default
Bottom left
Allowed range
Top left / Bottom left / Bottom right / Top right
Description
The default is bottom left.

Horizontal margin

English item name
Brand horizontal offset (pixels)
Input name
InpTriBrandX
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.

Vertical margin

English item name
Brand vertical offset (pixels)
Input name
InpTriBrandY
Default
10
Allowed range
Integer (pixels)
Description
Negative values are treated as 0, and values above 4000 are treated as 4000.
8

Usage specifications

Display only

It does not place, modify or close orders. There are no notifications or emails either.

History and initial values

Values on the forming bar are updated. Differences in data provider, symbol, timeframe and history start position affect the values and initial values.

Display units

Check the scale of the separate window. Do not treat the state bar heights, price differences and ratio displays as the same scale.

Brand display

Shows Produced by Trilogy Inc. and a QR code to https://www.trgy.co.jp/. When the same medium is used on the same chart, the display is shared. There is no account authentication.

For on-screen display only

The display is a record of calculation results. It does not direct trading decisions and does not guarantee future price movements.

9

Troubleshooting and usage notes

No display / blank partway

Level is neither a level of CCI itself nor pips; it is the lower limit of the product of CCI and Force. It depends on the unit and size of price changes and on tick volume, so the same value does not mean the same strength across symbols, data feeds or timeframes. Changing only the displayed digits does not change the formula. Even if Level is lowered, the display is blank when the signs disagree or one side is 0, and nothing is drawn when tick volume is 0. The CCI period and the MA up to the previous bar are needed, and on the forming bar the bars change with price and volume. Check the required history and inputs, and distinguish a blank from a calculation error.

The input is not accepted

Check the ranges and combinations in the settings. Inputs for methods not in use must also be within the allowed range.

Values differ from those with other settings

CCI of the selected price=(price−period average)/(0.015×mean absolute deviation). If the deviation is 0, CCI=0. Force=(current value−previous value of the MA of the selected price)×tick volume of the current bar. If CCI×Force>=Level and both are strictly positive, +1; if both are strictly negative, −1. Otherwise there is no value; it does not draw a bar of 0.

Displays overlap

Use separate charts, or adjust the brand position and margins. The images can also be checked at full size.

If the first display does not appear, check history loading and the input ranges. If an earlier display has stopped updating, first check the price feed and the terminal's connection status.

10

Technical information and specification details

Calculation and reference range

CCI of the selected price=(price−period average)/(0.015×mean absolute deviation). If the deviation is 0, CCI=0. Force=(current value−previous value of the MA of the selected price)×tick volume of the current bar. If CCI×Force>=Level and both are strictly positive, +1; if both are strictly negative, −1. Otherwise there is no value; it does not draw a bar of 0.

Handling of initial values and exceptions

Level is neither a level of CCI itself nor pips; it is the lower limit of the product of CCI and Force. It depends on the unit and size of price changes and on tick volume, so the same value does not mean the same strength across symbols, data feeds or timeframes. Changing only the displayed digits does not change the formula. Even if Level is lowered, the display is blank when the signs disagree or one side is 0, and nothing is drawn when tick volume is 0. The CCI period and the MA up to the previous bar are needed, and on the forming bar the bars change with price and volume. Check the required history and inputs, and distinguish a blank from a calculation error.

Package contents and dependencies

Only MT5 itself and this manual. Account authentication, external indicators and DLLs are not required.